LBRY Block Explorer

LBRY Claims • hitachi-error-code-list-hitachi-error

e64d8134d2725f83651111e025ac638c43b62a24

Published By
Created On
31 Mar 2022 17:33:59 UTC
Transaction ID
Cost
Safe for Work
Free
Yes
Hitachi Error Code List | Hitachi Error Code p09
This video is to help assist with All Error Codes for hitachi ke sabhi Error code Aapko mill jayge, Error code indoor or outdoor se pata karte hai, jaise konsi light kitni baar blink ho rahi hai..
ERROR CODE KI PURI LIST K LIAY APNA MAIL ID COMMENTS ME BTAY THANK YOU..
AC Se Related Intresting Video Dekhne k Liay Hmare Channel AC REPAIR TIPS!! ko Subscribe Kare.Hitachi Inverter air conditioner error code chart,Hitachi Ac error code list,Hitachi air conditioner error code chart,Hitachi Inverter split Ac blinking error code list

LIKE | COMMENT | SHARE | SUBSCRIBE
=====================================
==========


Website https://www.tecengineering.in/
Facebook https://www.facebook.com/tecengineeri...
WhatsApp Group :- https://chat.whatsapp.com/FF44hTGJ2kSKHTWEzzRBY2
whatsApp Group :- https://chat.whatsapp.com/KMr7yHHiW5kLpnp1ic6bbZ
Telegram Group :- https://t.me/joinchat/R2n5DxifyxVSWazZls_wQg


================================================
==============
WhatsApp Number +917036691232
E-Mai :- tecmep46@gmail.com
Any hvac & mep design & Drafting please contact me

Panasonic AC Error Code | Panasonic Error Code List
https://youtu.be/4HiZhoxKsbQ

LG AC Error Code | LG inverter split AC error CH 12, CH 10, CH 05
https://youtu.be/m_RWbqO8TeI

Haier Ac Error Code | Haier Ac f1 Error Solution
https://youtu.be/cesZBLTo1bg


P01 - Pressure ratio.
P02 - High pressure increase.
P03 - Inverter current high.
P04 - Inverter fin temperature increase.
P05 - Discharge gas temp. increase.
P06 - Low pressure decrease.
P09 - High pressure decrease.
P0A - Demand current control.               
P0d - Low pressure increase.
P11 - Pressure ratio decrease.
P12 - Low pressure increase.
P13 - High pressure increase.
P14 - compressor overcurrent.
P15 - Discharge gas temperature increase/ Low pressure.
P16 - Discharge gas super-heat.
P26 - High pressure decrease.              
01 - Failure Fan Motor, Drain Discharge, PCB, Relay.
03 - Incorrect Wiring. Failure PCB. Tripping Fuse. 
05 - Incorrect Wiring.
06 - Voltage and Power Supply issue, Incorrect Wiring.
07 - Over Refrigerant Charge, Expansion Valve Open Lock.
08 - Ref. Leakage.
09 - Failure of Fan Motor.
11 - Inlet Air Thermistor.    
12 - Outlet Air Thermistor.
14 - Gas Piping Thermistor.
19 - Failure of Fan Motor.
21 - High Pressure Sensor.    
22 - Outdoor Air Thermistor.
23 - Discharge Gas Thermistor on Comp.
24 - Evaporating Thermistor.
29 - Low Pressure Sensor.
...
https://www.youtube.com/watch?v=6WzAd7MyRh8
Author
Content Type
Unspecified
video/mp4
Language
English
Open in LBRY

More from the publisher

Controlling
VIDEO
IMPOR
Controlling
VIDEO
VECTO
Controlling
VIDEO
ENTER
Controlling
VIDEO
LG AC
Controlling
VIDEO
HVAC
Controlling
VIDEO
HVAC
Controlling
VIDEO
VRF A
Controlling
VIDEO
HEAT
Controlling
VIDEO
VENTI